Make up air W/ Devin Skipper

Make & share a podcast clip

Keep the exact passage and a link to the full episode. Choose up to three minutes, with enough context to be fair to the speaker.

Preview uses this episode’s audio. Browser audio export, when supported, takes the length of the selected clip. Nothing plays until you choose Preview.

Devin Skipper comes on the podcast to give you an introduction to make-up air systems and explain their purpose. This time, we pull out all of the initials: MAU, MUA, DOAS, and MHGRV.

Make-up air is outdoor air that we bring in to replace exhausted indoor air, usually in commercial systems. We use dedicated systems to bring in humidity-controlled air to rebalance the building to a positive pressure; hotels, restaurants, and medical facilities with significant exhaust need fresh air to compensate for that exhaust and negative pressure. Unsurprisingly, design is critical for these systems, especially in humid climates.

For example, in a restaurant, fresh air must come in from an area where it can add positive pressure without too much humidity. So, exhaust devices AND make-up air units will be on the roof. Undesirable infiltration occurs through cracks and under doors and usually isn’t enough to make a satisfactory difference in the building pressure. In commercial facilities, excess negative pressure can make it difficult for people to open doors, which could present a safety hazard for building occupants.

MHGRVs (modulating hot gas reheat valves) modulate discharge gas through a reheat coil. These components allow a system to keep running and maximize dehumidification without overcooling the space. When a reheat valve opens, the condenser valve closes and redirects discharge gas to the reheat coil, but they are NOT the same parts that facilitate hot gas defrost. These also keep systems from tripping on high head pressure.

Devin and Bryan also discuss:

  • High-latent markets and design conditions
  • Measuring pressure (in wc)
  • Excess positive pressure complications
  • Floor drains and negative pressure
  • Reheat strategies
  • MUA fans vs. units
  • MUA controls

Learn about Refrigeration Technologies HERE.

If you have an iPhone, subscribe to the podcast HERE, and if you have an Android phone, subscribe HERE.

Work through this with the trade.

Highlight a short passage, or bring a question about a specific moment into HVAC No Bull Forum.

Discuss this reference → Related forum discussions

Comments

Advanced Refrigerant Recovery: Best Practices for Diverse Systems and Environments
The A2L & Refrigerant Transition – Short #302
Invented For Techs, by Techs: Inside Refrigeration Technologies’ “The Lab”
The Ethics of IAQ – Testing vs. Remediation Conflicts – Short #301
Is 400 CFM per Ton Always Right? w/ Ty
The MERV 15 Filtration Physics – Short #300
Tips for Being On Call w/ Ty
The Florida “M-Word” – Legal Boundaries & Tech Communication – Short #299
Becoming a GRIT Host or Mentor w/ Leilani
Behind the Drywall – The Psychrometrics of a Hidden Moisture Failure – Short #298

Author:

The HVAC School site, podcast, and tech tips are
made possible by generous support from