The Deep End with Roman Baugh: Live Call, Grounded Compressor, Mitsubishi Mini-Split

Make & share a podcast clip

Keep the exact passage and a link to the full episode. Choose up to three minutes, with enough context to be fair to the speaker.

Preview uses this episode’s audio. Browser audio export, when supported, takes the length of the selected clip. Nothing plays until you choose Preview.

In this short podcast, Roman Baugh takes over with his new series, “The Deep End,” where he shares tech support conversations. This time, Roman is on the other end of a live tech support call about a grounded compressor with an existing Mitsubishi mini-split (Mr. Slim heat pump). The unit in this case had an unclear service history due to the homeowner moving in recently.

In this issue, the compressor kicked on and kicked off immediately. After the technician in this scenario told tech support that he had no continuity from the compressor to ground, tech support asked him to check the resistance (which was 43 ohms from black to ground and 43 from white to ground). Tech support concluded that the compressor was grounded, and it needed to be replaced (along with the PCB). However, the resistance disappeared mid-call, and intermittent resistance readings don’t always indicate a failed winding; it’s worth noting that cool ambient temperatures that enable liquid refrigerant to migrate into the compressor could potentially skew electrical readings.

Roman recommended shutting the system down and trying to get the system to run. His rationale was that if the unit ran and didn’t keep stopping, the system may have been overcharged or lacking a crankcase heater. However, that did not show any improvement in operation; the compressor rattled for about a second and shut off. A resistance test confirmed that the compressor was grounded, pointing to a mechanical issue with the compressor and not just a one-off instance of refrigerant migration. This type of failure can happen when there are repeated instances of liquid refrigerant in the crankcase over time.

 

Have a question that you want us to answer on the podcast? Submit your questions at https://www.speakpipe.com/hvacschool.

Purchase your tickets or learn more about the 7th Annual HVACR Training Symposium at https://www.hvacrschool.com/symposium.

Subscribe to our podcast on your iPhone or Android.

Subscribe to our YouTube channel.

Check out our handy calculators here or on the HVAC School Mobile App for Apple and Android.

Work through this with the trade.

Highlight a short passage, or bring a question about a specific moment into HVAC No Bull Forum.

Discuss this reference → Related forum discussions

Comments

Next-Gen Filtration – Pressure Drop, MERV 16, and Bypass Prevention w/ Chris Howells
The Fuse Only Blows When You Leave – Short #307
Questionable CO Alarms w/ Bill Spohn
Same Charge, Different Numbers – Short #306
Tech, Mechanic, or Craftsman? Finding Your Fit in HVAC
Normal Subcooling, Hidden Restriction – Short #305
Airflow Serenity w/ Alex Meaney
Less Compressor, More Suction Pressure – Short #304
Mastering Your Meter Advanced Functionality with Louise Kellar (UEi Test Instruments)
Premature Coil Failure in Ductless Mini-Splits & VRF Equipment – Short #303

Author:

To continue you need to agree to our terms.

The HVAC School site, podcast, and tech tips are
made possible by generous support from