In this short podcast episode, Bryan dives a bit into equipment sizing rules of thumb and why square footage does NOT equal tonnage in today’s world. Many rules of thumb exist in the industry, and one is a load calculation rule stating that you can size the HVAC for a house at 500 square feet per ton.

Old houses are leaky and poorly insulated compared to new homes, which results in large energy loads but allows the homes to dry themselves out, as moisture could leak out before it could cause trouble indoors. Large loads and leaky envelopes made 500-600 square feet per ton a sensible rule.

Homes built within the last few decades have a lot more insulation and are tighter, and they have smaller sensible heat loads. However, they’re a lot more moisture-prone, especially when moisture can’t escape via proper ventilation paths. The 500 square-foot rule of thumb overshoots the latent capacity and leads to short cycling due to oversized equipment. Enter ACCA Manual J, which presents a load calculation method that is very good, but it has barriers to entry; it is very rigorous, has a learning curve, and can be a hassle. One thing is clear, though: load management is key, especially latent load management.

At this time, we measure energy efficiency in terms of metrics like SEER, but the future is pointing to peak load management as the answer: getting the right power draw at the right moments instead of high general efficiency. Modernizing hot deck-cold deck systems with steady-state, constantly running systems might be the way to go, especially if we utilize energy storage and modern variable-speed technologies.

The new rule of thumb is to think like a building scientist and apply new tools to concepts that have stood the test of time. Low peak loads and steady-state operation are often the way to go with high latent loads in homes built to the most recent building codes and standards.

 

Have a question that you want us to answer on the podcast? Submit your questions at https://www.speakpipe.com/hvacschool.

Purchase your tickets or learn more about the 7th Annual HVACR Training Symposium at https://www.hvacrschool.com/symposium.

Subscribe to our podcast on your iPhone or Android.

Subscribe to our YouTube channel.

Check out our handy calculators here or on the HVAC School Mobile App for Apple and Android.

Work through this with the trade.

Highlight a short passage, or bring a question about a specific moment into HVAC No Bull Forum.

Discuss this reference → Related forum discussions

Comments

Advanced Refrigerant Recovery: Best Practices for Diverse Systems and Environments
The A2L & Refrigerant Transition – Short #302
Invented For Techs, by Techs: Inside Refrigeration Technologies’ “The Lab”
The Ethics of IAQ – Testing vs. Remediation Conflicts – Short #301
Is 400 CFM per Ton Always Right? w/ Ty
The MERV 15 Filtration Physics – Short #300
Tips for Being On Call w/ Ty
The Florida “M-Word” – Legal Boundaries & Tech Communication – Short #299
Becoming a GRIT Host or Mentor w/ Leilani
Behind the Drywall – The Psychrometrics of a Hidden Moisture Failure – Short #298

Author:

The HVAC School site, podcast, and tech tips are
made possible by generous support from