Moisture & Humidity Problems #Live
In this first live episode we discuss moisture and humidity issues in HVAC
Read more
Fan (Blower) Efficacy
For those of you who use the MeasureQuick app for system diagnosis and performance testing, you may have noticed the “fan efficacy” results and wondered what it is. It is simply the CFM output of the system divided by the wattage used by the blower. It is only for the blower motor and has nothing […]
Read more
What Willis Understood 
I've been reading a book called Cool: How Air Conditioning Changed Everything, and it got me interested once again in the history of air conditioning and refrigeration. Like many things, the people who are credited with “inventing” are the ones dogged enough to make an idea commercially successful, not the idealists forever tucked away in the […]
Read more
What is “Cascade” Refrigeration?
Photo Courtesy of Emerson What is Cascade refrigeration? “Cascade refrigeration” is a term you will hear more and more over the coming years, and while some of the systems may be very complex, the concept is actually pretty simple. Some refrigerants are well-suited for high and medium-temperature applications, and some are better suited for lower-temp […]
Read more
Non-Condensibles
Eric Mele and Joe Shearer join Bryan to discuss the challenging issue of diagnosing and rectifying non-condensibles in the circuit
Read more
Short #67 – Defrost Termination and Failsafe
In this episode we quickly cover the words termination and failsafe and what they mean in relation to refrigeration defrost
Read more
Double Lugging, A Common Mistake
Connecting more than one wire on or under a single lug or connection point is called “double lugging,” and it is ONLY allowed in line voltage wiring under one condition, according to NEC 110.14: If the terminal, lug, or connector is specifically rated for more than one wire In the case of a conductor splice, […]
Read more
The Two OTHER EPA violations
We all know (or should know) that venting refrigerant is a big no-no and can result in trouble from the EPA. There are many other potential violations, but two of them can easily occur if you aren't thinking ahead at the disposal of mercury and oil. Mercury is found in fairly large quantities in the […]
Read more
Cleaning Condenser Coils Still Matters
There was a story that came out recently based on an ASHRAE study performed by David Yuill from the University of Nebraska. The study appeared to indicate that condenser coil cleanliness makes no difference on system performance and efficiency. Those of us who have worked in the field know that coil cleaning matters because most […]