The “Approach” Method of Charging and Condenser Efficiency
Is it too cold to set the charge?
Charging Systems with Accumulators
Flash Gas
Is It OK To Top Off With R410a?
Checking the Charge on a Heat Pump in the Winter
Know the Limits of Subcooling
The “5 Pillars” of Residential A/C Refrigerant Circuit Diagnosis
Testing, Recovery, and Charging a Sealed System
#charging
Tech Tips:

We have discussed many methods for checking a refrigerant charge without connecting gauges over the last few years. Recently, I've been thinking about the “approach” method of charging that many Lennox systems require. What is the Approach Method? The “approach” simply refers to the temperature difference between the liquid line leaving the condenser and the […]
Read more

I've heard the phrase, “It's too cold to set the charge!” for as long as I've been in the trade. I've also heard some variations of, “We need to come back and set the charge,” or, “We need to come back to do XYZ [some other thing].” Granted, there are cases where you do actually […]
Read more

In air conditioning service, we don't always see systems with accumulators. In fact, they are pretty uncommon unless you work on a lot of heat pumps. However, as heat pumps gain popularity, charging systems with accumulators will be a good skill to have in your tool bag. We are Carrier dealers in Florida, so we […]
Read more

When we say that there is “flash gas” at a particular point in the system, it can either be a bad thing or a good thing, depending on where it is occurring. Flash gas is just another term for boiling. It is perfectly normal (and required) that refrigerant “flashes” or begins boiling directly after the […]
Read more

I am consistently surprised by how much false information still circulates out in the field, and one of the ones I hear often is the idea that you cannot or should not “top-off” or recharge R410a systems on top of an existing charge of R410a when the system is low. So, to be clear, before […]
Read more

When you ask many people nowadays how to check the charge on a heat pump during low outdoor temps, they will say that you need to “weigh in and weigh out” the charge. While this may be an effective method, it isn't always practical. Now, if you are making a refrigerant circuit repair, weighing out […]
Read more

This article was written by RSES CM and excellent market refrigeration tech Jeremy Smith. Thanks, Jeremy! I frequently see techs online struggling with charging or troubleshooting refrigeration equipment and using subcooling as a diagnostic or charging method. Please don't do this unless you understand it fully. Many times, trying to charge a refrigeration system to […]
Read more

Suction pressure, head pressure, subcooling, superheat, delta T. Taking all five of these calculations into account on every service call is critical. Even if you must do further diagnostic tests to pinpoint the problem, these five factors are the groundwork before more effective diagnostics can be done. I would also add static pressure as an […]
Read more

There are many appliances with compression refrigeration circuits that do not have ports installed for testing, recovery, charging, and evacuation. Â These can include window units, PTACs, fountains, refrigerators, and much more. This fact presents a challenge any time you suspect or know there is a refrigerant circuit issue. How can you diagnose and repair when […]
Read more