Controls, Thermostats & Boards
This tech tip is the final installment in our short series on using oscilloscopes to troubleshoot communicating systems. This time, we're focusing on troubleshooting communication issues in commercial refrigeration systems. Imagine this scenario: you've got a refrigeration system acting up, and the comms network, whether it's LON or MOD-bus, seems a bit flaky. Let me […]
Read more
This tech tip about RS-485 communication is the third installment in a four-part series about oscilloscopes. It's a primer for the final installment about using an oscilloscope for diagnosis. I owe a special thanks to Jeremy Smith for sharing the information on Danfoss and for sparking my curiosity surrounding this type of communication. Let's talk […]
Read more
This is part two of our four-part series on oscilloscope fundamentals. Special thanks to Andrew Holden for his contributions. In our last tech tip on oscilloscopes, we learned about some safety basics, waveforms, and measurements. We’re going to dive a little deeper into systems and settings on the oscilloscope in this tech tip. Systems are […]
Read more
This tech tip is the first in a four-part series on using oscilloscopes. I'd like to give a special thanks to Andrew Holden for his contributions to this particular tech tip. When we want to measure voltage between two points, we reach for a multimeter. A multimeter can tell us the average electrical potential between […]
Read more
A while back, I had a tech who was having some trouble finding a 35 PSI (2.41 bar) make-on-fall pressure switch. One adjustable switch in the catalog said (SPDT), but he didn't quite understand what that meant. In that case, it means single-pole, double-throw, and the “double-throw” part means that the switch has terminals in both the […]
Read more
You have seen the C terminal on a dual run capacitor before. You have also seen the C terminal on a compressor. It stands to reason that they would both connect together, right? They don't connect, and they aren't even related, at least not in the way you think. In both cases, the C denotes […]
Read more
Educators love lockout relays, and we also love pretending you will still see them out in the field all the time. Sometimes, I have to look myself in the mirror in the morning and sadly repeat, “Lockout relays are dead.” I have to say it several times before the reality sinks in. Before I get […]
Read more
There are three things we never discuss at the dinner table: religion, politics, and which wire to break with your float switch. A float switch fills with water whenever there is a drain backup, and it breaks power to one of the low-voltage wires. We clearly want the HVAC system to stop producing more condensate, […]
Read more
When I first started in the trade, we used to run into shielded control cable on the Carrier Comfort Zone 1 zoning systems and also on a Carrier VVT system I used to maintain at a bank. I knew it had something to do with electrical “noise” and that communicating systems often called for it, […]
Read more