What’s So Wrong With “Beer Can Cold”?
First off, if you've never heard the term “beer can cold,” you are either not in the trade, or you have been living a pretty sheltered existence. I started as a tech apprentice when I was 17 years old, and on my first day in the truck, my trainer grabbed the suction line of a […]
Read more
Charging Systems with Accumulators
In air conditioning service, we don't always see systems with accumulators. In fact, they are pretty uncommon unless you work on a lot of heat pumps. However, as heat pumps gain popularity, charging systems with accumulators will be a good skill to have in your tool bag. We are Carrier dealers in Florida, so we […]
Read more
The Pressures Look Good
Yeah? Well, how do you know? What should they be? What are the outdoor and return air temperatures? What SEER rating is the equipment?  These are the questions I ask every single time a technician says the phrase,  “But the pressures look good for [insert refrigerant of choice here].”  When they can’t answer the questions […]
Read more
TD of Refrigeration Evaporators
We have discussed DTD (design temperature difference) quite a bit for air conditioning applications, but what about refrigeration? Let's start by defining our terms again. Suction Saturation Temperature The saturation temperature is the temperature at which the refrigerant will be at a given pressure if it is currently changing state. This change of state would […]
Read more
Know the Limits of Subcooling
This article was written by RSES CM and excellent market refrigeration tech Jeremy Smith. Thanks, Jeremy! I frequently see techs online struggling with charging or troubleshooting refrigeration equipment and using subcooling as a diagnostic or charging method. Please don't do this unless you understand it fully. Many times, trying to charge a refrigeration system to […]
Read more
Accumulator & Burnout Considerations
The suction line accumulator is designed to keep liquid refrigerant from entering the compressor while still allowing for oil return. The trouble is that if the oil return port/screen clogs, the accumulator can fill with oil and actually cause the compressor to fail. In addition to that, it can hold contaminated oil in a burnout. […]
Read more
The “5 Pillars” of Residential A/C Refrigerant Circuit Diagnosis
Suction pressure, head pressure, subcooling, superheat, delta T. Taking all five of these calculations into account on every service call is critical. Even if you must do further diagnostic tests to pinpoint the problem, these five factors are the groundwork before more effective diagnostics can be done. I would also add static pressure as an […]
Read more
Subcool and Liquid Line Length
The primary role of setting an appropriate level of subcooling is to ensure that we deliver a full line of liquid refrigerant to the metering device. We want to do this at: A pressure differential required by the metering device At a temperature and pressure no higher than required for maximum capacity and efficiency But […]
Read more
20° ΔT (Delta T), A Lazy Rule of Thumb
What should the delta T (ΔT) be? What do you mean!? 20 degrees, of course! We are referring to the air temperature drop across an air handling unit or evaporator coil in cooling mode. Actually, depending on who you ask, the answer will range between 18-22 degrees Fahrenheit. Heck, I’ve heard some insist that the […]
Read more