Refrigeration Circuit, Charging & Diagnosis
Receivers, which we sometimes call “liquid receivers,” are components that store refrigerant. You'll see it on everything from small self-contained refrigeration units to very large commercial and industrial systems. Many new techs who are used to residential air conditioning confuse receivers with accumulators. It's an understandable mistake; they both contain liquid refrigerant. The main difference […]
Read more
Does setting a thermostat too low cause an air conditioning system set in cool mode to freeze? The answer is no, at least not directly. However, low evaporator load (low return temperature or low airflow) and low outdoor ambient temperature can lead to evaporator coil freezing. Low indoor setpoint can lead to low return air […]
Read more
When we say that there is “flash gas” at a particular point in the system, it can either be a bad thing or a good thing, depending on where it is occurring. Flash gas is just another term for boiling. It is perfectly normal (and required) that refrigerant “flashes” or begins boiling directly after the […]
Read more
I was fresh out of school, working as an apprentice at my first real HVAC job, and I was listening in on a shop conversation between a few techs. They were talking about finding so many overcharged systems. One of the techs turns to me and says, “I had a unit yesterday that was so […]
Read more
Diagram above by Carrier It's really easy to put a liquid line drier in the proper location, but it's still more commonly installed in the WRONG location. Namely, people install it right at the condensing unit. (OK, it isn't that big of a deal, but I needed some dramatic emphasis.) Installing it at the indoor […]
Read more
The most common—and often most frustrating—questions that trainers and senior techs get asked sound something like this: “What should my ______ be?” or “My _____ is at ______. Does that sound right?” Usually, when the conversation is over, both the senior and junior techs walk away feeling frustrated because the junior tech just wanted […]
Read more
Delta T is the difference in temperature between two points of the same medium. It is commonly used by scientists and engineers to analyze the amount of heat transfer in a system. In general HVAC terms, it is the measurable change in temperature between an air input and air output. However, it could also be […]
Read more
You may have noticed that 3/8″ liquid lines are generally the norm in equipment 5 tons and under. We went to a job where the system had a 1/2″ liquid line, and it got me thinking about liquid line sizing and the ramifications of going larger or smaller on the liquid line. Liquid Line Basics […]
Read more
In residential, most techs and installers size the suction (vapor) and liquid lines to the stubs on the equipment. In larger built-up systems, sizing the suction and liquid lines is rarely the responsibility of the technician. But what happens if we show up to a job where the lines cannot be (reasonably) replaced because the […]
Read more